Tel:
China EAS Security System manufacturer
AllyTag Security Co., Ltd

Have AllyTag, Have Safety! 

Home ProductsSecurity Tag Detacher

High Sensitive Magnetic Detacher Teslameter 0 - 2000mT Measurement Scope

High Sensitive Magnetic Detacher Teslameter 0 - 2000mT Measurement Scope

    • High Sensitive Magnetic Detacher Teslameter 0 - 2000mT Measurement Scope
    • High Sensitive Magnetic Detacher Teslameter 0 - 2000mT Measurement Scope
    • High Sensitive Magnetic Detacher Teslameter 0 - 2000mT Measurement Scope
    • High Sensitive Magnetic Detacher Teslameter 0 - 2000mT Measurement Scope
  • High Sensitive Magnetic Detacher Teslameter 0 - 2000mT Measurement Scope

    Product Details:

    Place of Origin: China
    Brand Name: AllyTag
    Certification: CE Certificate / RoHS
    Model Number: AT-D012

    Payment & Shipping Terms:

    Minimum Order Quantity: Negotiable
    Price: Negotiable
    Packaging Details: 1Pc/Ctn; G.W: 1.50KGS/Ctn
    Delivery Time: Up To The Order Quantity; Or One Week Delivery For Stock
    Payment Terms: T/T, Western Union, L/C, Paypal For Small Amount
    Supply Ability: 10,000Pcs Per Month
    Contact Now
    Detailed Product Description
    Product Name: Gaussmeter / Teslameter Dimension: 150X70X30MM
    Color: Blue Weight: 450g
    Measurement Scope: 0~200mT, 0~2000mT Accuracy: 1%
    Resolution: 0.1mT; 1mT Usage: Test Magnetic Detacher Power / Gauss

     

    High Sensitive Gaussmeter 2000mT Magnetic Detacher Teslameter

     

     

     

    Specifications:

    Product Name Gaussmeter / Teslameter
    Dimension 150X70X30MM
    Weight 450g
    Color Blue
    Measurement Scope 0~200mT, 0~2000mT
    Accuracy 1%
    Resolution 0.1mT; 1mT

    Temperature Error

    -0.06%/°C

    Operating environment: Temperature

    -10°C~40°C

    Humidity

    35~75%

     

     

     

     

    Instruction: 

    This instrument is the magnetic field measuring instrument specially designed for field measurement. Its design concept of lightness, practicality and portability has been determined at the beginning of instrument design and its unique design of micro power consumption allows its battery life to be greatly improved.

     

     

     

    Main characteristics: 

     

    • With small volume, light weight and convenient carry, this instrument can meet the measurement requirements of various sites;
    • Adopt micro power consumption design. With long service life, the battery can be continuously used for more than 50 hours;
    • Can select transverse probe or axial probe;
    • Have judgment function of magnetic field polarity.

     

     

    Instrument Operating Instruction:

    High Sensitive Magnetic Detacher Teslameter 0 - 2000mT Measurement ScopeHigh Sensitive Magnetic Detacher Teslameter 0 - 2000mT Measurement Scope

     

    Step 1: Connection: connect the Hall probe with the instrument⑥;

    Step 2: Power on: Press the “ON/OFF” switch ②on the panel of handhold Gauss meter and there shall be display ①on the panel meter, it represents the instrument power has been energized and measurement can be done;

    Step 3: After the power is energized, firstly select a corresponding range ③according to the magnetic field size of the measured object.

    Step 4: Zero point correction: Place the Hall probe in the area whose magnetic field is zero. When the meter reading is not zero, adjust “Zero” ⑤potentiometer till the reading is zero.

    Step 5: Magnetic field measurement

    A. Place the Hall probe in the surface magnetic field of the measured sample, move the Hall probe and the magnetic field intensity can be directly read from the instrument, whose unit is mT and the magnetic field polarity also can be judged (When using transverse probe and the display value is “-”, the end side of the Hall probe faces N pole.

    B. The range button, the range is 2000mT when it is pressed and the range is 200.0mT when it bounces back;

    C. Contact the magnetic steel surface with Hall chip side in the practical measurement, the measurement result is closer to the actual value. When measuring with base plate side, the measurement result is little low, 1mT = 10 Gs.

     

     

    Instrument Calibration: 

    Place the Hall probe in the standard magnetic field and adjust the “Calibration” ⑦potentiometer with small slotted screwdriver till the instrument reading is consistent with the numerical value of the standard magnetic field. Generally, it will be required to calibrate the instrument only after the Hall probe is replaced.

     

     

    Remarks: 

    When you test, make sure the mark line face to yourself and the opposite press close to the permanence magnet.

     

     

    Usage: 

    High Sensitive Magnetic Detacher Teslameter 0 - 2000mT Measurement Scope

     

     

     

    Shipping Way:

    a. The fastest way by Express or  Courier, such as DHL, UPS, Fedex, TNT and so on;

    b. By Air shipment would be also fast, and sometimes cheaper than Express/ Courier;

    c. The chepest and normal way by Sea shipment, which is cost-saving. Normally it takes around 25-35days from China to countries all over the world. 

     

     

    Photos Present: 

    High Sensitive Magnetic Detacher Teslameter 0 - 2000mT Measurement Scope

     

    High Sensitive Magnetic Detacher Teslameter 0 - 2000mT Measurement Scope

     

    Contact Details
    AllyTag Security Co., Ltd

    Contact Person: Silvia Wong

    Send your inquiry directly to us (0 / 3000)

    AllyTag Security Co., Ltd
    Guangzhou, China
    Tel:86-20-29030939
    Privacy Policy China Good Quality EAS Security System Supplier. Copyright © 2018 - 2019 eassecurity-system.com. All Rights Reserved.